| PS-2012-SL
The PowerSTAR PS-2012-SL
has been designed for Solar Street Lighting applications requiring
highly efficient solar power generation capabilities. This
model is rated at 240W solar power input level.
PowerSTAR utilises Maximum Power Point Tracking (MPPT)
techniques to
extract maximum possible power from
standard PV solar panels.
Features
-
Advanced
MPPT control algorithm
-
Up
to 30% more power from solar cells
-
Fully
User Configurable
-
Ability
to save configuration settings on PC
-
Rapid
regulator upload of saved configuration settings
-
Data
Storage
for 400 days
-
Datalogging
of:
- Amp hours input
- Amp hours output
- Maximum battery voltage
- Minimum battery voltage
- Time to float
- Days to next equalisation
- Boost
- Equalisation
- Absorption
- Float
-
Lightning
induced transient protection
-
Solar
reverse polarity protection
-
Battery
reverse polarity protection
-
PC
Interface via RS232 port
-
Easy
to use graphic interface
Absolute Maximum Ratings
-
Maximum
voltage across battery terminals : 25V
-
Minimum
voltage across battery terminals : 0V
-
Maximum
voltage across photovoltaic terminals : 26V
-
Minimum
voltage across photovoltaic terminals : -26V
-
Maximum
continuous input current from PV array : 20A
-
Maximum
continuous input power from PV array : 240W
-
Maximum
continuous output current to battery :20A
-
Maximum
continuous output power to battery :240W
-
Maximum
continuous load output current : 10A
-
Maximum
continuous load output power : 120W
-
Maximum
ambient operating temperature ; 60°C
-
Minimum
ambient operating temperature: -30°C
-
Maximum
lightning induced spike/terminal pair :100A
-
Maximum
lightning induced energy across all terminals : 1.8J
Metering
Range
-
Maximum
battery voltage :17V
-
Minimum
battery voltage : 7V
-
Maximum
solar voltage : 22V
-
Minimum
solar voltage : 0V
-
Maximum
battery current :20A
-
Minimum
battery current : -10A
Metering
Accuracy
User Settings
-
Boost
voltage
-
Equalisation
voltage
-
Equalisation
hold time
-
Equalisation
frequency
-
Equalisation attempts before returning to normal operation
-
Absorption
voltage
-
Absorption
hold time
-
Float
voltage
-
Boost
return voltage
-
Load
disconnect voltage
-
Instantaneous
load disconnect
-
Load
reconnect voltage
-
Solar
open-circuit connect voltage
-
Solar
sunset voltage
-
Solar
sunset time
-
Solar
sunrise voltage
-
Solar
sunrise time
-
Load
on time
-
Load
on conditions (sunset, before sunrise, external button)
-
Load
off conditions (timeout, sunrise, external button)
Options
-
·
Temperature compensation
-
·
Discrete load disconnection mode
-
·
Advanced diagnostics for rapid field analysis
|